top of page
Application: Hydro Power Pipe Monitoring
Solution: Solution: Ultraflux Ultrasonic Flowmeter
Application
-
Hydro Power Station feed pipes from the dam.
-
Flows are measured to check for leaks
-
Flow velocities were high
-
The pipe could not be drilled or cut
-
The system had to be vandal resistant!
Application Details
-
Pipe size: 1.5m
-
Flowrate: 6.8 m3/sec
Solution
-
An Ultraflux Ultrasonic Clamp-on flowmeter was specified and installed.
-
Special sensor mountings were designed by Flowline.
-
No flow shutdown was needed.
-
The control unit outputs data to an automatic control/shutdown system. telemetry system.
Equipment Specified
-
Ultraflux clamp-on probes

Application

Solution
Applications
-
Pumped sewer flows
-
Effluent flows
-
Drinking water distribution
-
Process flow
Key Words
-
High-velocity
-
Retrofit
-
No pipe drilling
-
Vandal-resistant


Installation